Mahindra Diesel Generators

The generators come in different ratings and you can choose the Diesel Generating set to suit your Load requirements for Standby Power Generation. If you have unbalanced Load conditions on 3 Phases you must use 1 Phase Alternator and if you have Balanced Load on 3 Phases you must use 3 Phase Generators. Single Phase Generator is easily configured for 3 Phase Load. In unbalance Load Conditions the generators may start hunting if it is 3 Phase Generator. 

Genset Rating KVA/KW 12.5/10 15/12 20/16 25/20 30/24 35/28 40/32 45/38
Phase 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3
Current (AMPS) 17 21 28 35 42 49 56 63
Fuel consumption gms/BHP/Hr 167 167 166 160 157 157 165 165
Fuel consumption in Ltrs./Hour** 2.7 2.7 3.1 4.1 5.5 6.4 8.2 8.2
Weight in Kg. 485 485 590 685 765 765 1035 1035
Engine Model M&M 255/2185 GM 255/2185 GM 275/3255 GM 575/4335 GM NE452/4385 GM NE457/4445 GM G804 G804
BHP @ 1500 RPM 17.5 17.5 25 33 38 44 56.5 56.5
Nos. Cylinder 2 2 3 4 4 4 4 4
Bore (mm) 88.9 88.9 88.9 88.9 94 94 111.2 111.2
Stroke (mm) 110 110 101.6 101.6 110 115 120 120
Compression Ratio 19.5:1 19.5:1 18:1 18:1 18.5:1 19.4:1 15.6:1 15.6:1
Governing Mechanical Class A1  
Lube Oil Specification M & M Single Star / Double Star / 20W40  
Lube Oil Sump Capacity in Ltr. 5.1 5.1 7.1 9.4 8.6 8.6 11 11
Voltage 415 415 415 415 415 415 415 415
Frequency 50 50 50 50 50 50 50 50
Cable Size 4 Core (copper) sqmm 10 10 10 10 16 16 16 16
Battery Rating  AH 75 75 75 75 88 88 120 120

Mahindra is an approved vendor for standby power generation of BTS sites.

All Diesel Generator installations require site planning and the installation company must know:

1. Exact power requirement under peak load in KVA/KW.

2. Noise tolerance both in the building and in the neighbor-hood.

3. Mains supply fluctuation range.

4. Location of the Diesel Generator with adequate free space.

5. Indoor or outdoor installation.

6. Earthing available and required.

7. Vibration tolerance levels.

 

Recom's Experience is that every site requires different planning for standby generation of power be it for hospital, shopping mall, home, factory or any other installation.

 

Normally two earths are required at every DG Set installation site. These earths must be separated by a distance of more than 1 meter minimum.  one earth is connected to the body of the Diesel Generator and another to the Neutral terminal of the alternator.

 

Besides these a Manual switch of adequate rating is required to by pass diesel generator for maintenance or fault.

 

Mains may require stabilizers servo or automatic to correct the incoming power supply. These stabilizers must have HRC series fuses to cut off the supply in event of a short circuit on the load.

 

If an AMF Panel is installed make sure that Battery charging is on during the idle period so that Battery is charged to give cranking power to the diesel engine.

 

Diesel engines require servicing by the authorized service provider at regular intervals, normally at 250 hours of operation.

 

For 3 Phase unbalanced load it is preferable to use single phase alternator and for balance load 3 phase alternator must be used.

 

For Sound Proofing a Canopy is used to dampen the sound and some other precautions are required for sound proofing.